Design and Control of a Solar Photovoltaic Fed Asymmetric Multilevel Inverter Using Computational Intelligence

Main Article Content

Dr. Rambabu Chunduri, Benisha Gracelin , Dr. Dishore Shunmugham Vanaja,Subhashree Priyadarshini, Aradhana Khillo,Bibhu Prasad Ganthia

Abstract

Selective harmonic mitigation method is primarily used in the suppression of lower order harmonics. The Bee colony
optimization method is used to implement a SHE technique in this paper; the reduced switch thirty-one stage inverter
receives input voltage from the photovoltaic system. A stable voltage is maintained at the photovoltaic panel's output through
a SEPIC converter. Grey Wolf Optimization is used to boost the efficiency of the photovoltaic system. Multi Carrier
modulation method is often used to reduce the current and voltage harmonics in the inverter. Additionally, the proposed BCO
method is compared with genetic algorithm based SHE method. The proposed suggested framework has been validated using
Matlab simulation, and the prototype results have been validated using DSPIC30F2010 controller.

Article Details

How to Cite
Dr. Rambabu Chunduri, Benisha Gracelin , Dr. Dishore Shunmugham Vanaja,Subhashree Priyadarshini, Aradhana Khillo,Bibhu Prasad Ganthia. (2021). Design and Control of a Solar Photovoltaic Fed Asymmetric Multilevel Inverter Using Computational Intelligence. Annals of the Romanian Society for Cell Biology, 25(6), 17094–17107. Retrieved from http://www.annalsofrscb.ro/index.php/journal/article/view/8999
Section
Articles